For drone firms

You already take the photos. Hand over a report with them.

Upload the thermal photos from your flight, place a grid on each block of panels, review what the app flags, and send your client one private link.

A model of a real roof. The heat under the drone is the real thermal photo, and the marks behind it are the ones the app gave.

From flight to report

What you upload

The files your camera saved, unchanged

Upload the thermal photos straight from the memory card, many at once or as one zip. A thermal camera file holds a reading for every pixel beside the picture you see. The app reads those and draws its own white hot picture, so the colour scheme you flew with does not matter.

A screenshot, or a picture sent through a chat app, has lost those readings. If it is in a colour scheme the app turns it back and asks for the original.

Full photos have been tested with files from one camera model, the DJI Zenmuse H20T. DJI has no connection with PanelProof.

What you do

Four steps, all in the browser

  • Start an inspection and write down the camera, the sun, the wind and the cloud. The report prints what you recorded.
  • On each photo, click the four corners of a block of panels and type its rows and columns.
  • Review the panels the app flags. Confirm, change or reject each one.
  • Have your lead sign the report, and make a client link.

A real drone photo with two grids on it. Each cell becomes one checked panel with its own row and column.

What the app said

Photo 3, row 4, column 6

Suspected fault, type not clear

It stands 14.3 spreads above the ordinary panels of this inspection.

Your decision

No fault NSuspected fault FCannot tell C

Big enough

Each panel needs at least 24 by 40 pixels

The app checks panels at 24 pixels wide and 40 tall. A panel that covers fewer pixels than that in your photo is marked "too small" and sent to review, because the picture may not hold enough to judge.

What your client gets

One private link to a signed report

  • The report as a PDF, and a CSV with one row for every panel.
  • Every finding beside the picture it was seen on.
  • A button that checks the files against the fingerprints recorded when your lead signed.
  • Nothing they can change. You can switch the link off at any time.

Thermal inspection report

Rooftop plant, Catanzaro

Findings are suspected faults seen in thermal pictures. This report is not a safety certificate and is not a statement that the inspection meets any standard.

PicturesFull thermal photos, cut into panels with the grid
Panels checked1,485
Flagged for a person638
Not flagged by the app847
Photo 3, row 4, column 6Suspected fault, type not clear
Photo 5, row 11, column 2Suspected fault, type not clear
Photo 1, row 2, column 12Suspected fault, type not clear

Model pp-crops-0.1.0-level-camera. Review rule review-chooser-0.1.0.

What to tell your client

Say what the report is, and what it is not

A finding is a suspected fault seen in a thermal picture, confirmed by your technician. It is not a measurement of temperature, not a safety certificate, and not a statement that the inspection meets any standard. On 3,002 test pictures the fault finder missed 8 of every 100 faulty panels.

The measured results

Price

Priced on request

Tell us how many panels you fly in a month and we will reply with a price.